Technical Data and Features of the Halls

Hall 1 2 3 4 5 6 7 Under linkway 8.0 8.1 Remarks
Length (m)
(approx.)
203.4 392.3 415.1 218 201.5 220 201.5 215.2 175.5 161
Width (m)
(approx.)
45.7 / 102.5 84.5 95 81 79 81 79 36.2 79 79  
Gross exhibition
area (sqm)
14,000 33,412 42,951 20,250 16,682 20,250 16,751 7,894 13,825 12,700
Load bearing
capacity
(kg/sqm)
5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000 1,800 Special conditions apply to double storey stands in hall 8.1:
  • Maximum floor loading is 1,800kg/sqm
  • Points load can only support up to 6,000kg
  • The minimum distance between columns has to be 400cm
  • Base plates of 50cmx50cm are compulsory on double storey stand columns
  • Take into account the load limits and dimensions of the goods lifts in hall 8
Height of hall (m) 10.0 13.4/10.0 10.4 10.4 11.2 10.4 11.2 5.5 6.9 10.0 Stand construction height is a maximum of 6 metres, except for stands located:
  • Under the linkway in halls 2 and 3: 4 metres
  • Under the linkway between hall 4, 5, 6 & 7: 4 metres (no rigging)
  • Some areas of hall 2: 4 metres
  • Some areas of hall 3: 3.95 metres
Minimum entrance
dimensions for
loading/unloading
(width x height) (m) (approx.)
6.75x5.8 4.5x4.2 6x5 6x5 6.14x6 6x5 6.14x6 4.95 4.2x6.2 NA There is no vehicle ramp to Hall 8.1, cargo access is via goods lifts only.
Goods lift 8.1
Max weight - 4,000kg
Size - 2.5mx3.6m
Door width - 2.65m
Door height - 2.1m
Goods lift 8.2, 8.4 & 8.5
Max weight - 6,000kg
Size - 2.5mx5.4m
Door width - 2.65m
Door height - 2.7m
Goods lift 8.3
Max weight - 4,000kg
Size - 2.5mx3.6m
Door width - 2.7m
Door height - 2.3m
 
Maximum entrance
dimensions for
loading/unloading
(width x height) (m) (approx.)
7.96x10 8.42x8.9 6x8.8 9x8 7.5x5.5 9x8 7.5x5.5 16.98 4.2x6.2 NA
Distribution boards lll 400V (cetac 5 wholes). Electricity supply: 63 amps/utility duct Electricity, compressed air and water are supplied to
the stands in the halls via underground utility ducts.
In general, service chests are spaced approximately 8 metres apart.
Compressed air 2 ducts per service chest. Compressed air connection: 1,000 litres/min. 6.5 bar
Water supply 2 ducts per service chest. Water connection: ½ inch, 4 bar, 32 mm pipe connection from ring main
Gas No gas supply is available in the venue.
Sewer points
(inside the chest)
113 284 346 185 130 164 130 43 120 88  
Ceiling lighting General hall lighting is provided to a level of between 100 and 150 lux per square metre.  
Heating and ventilation General heating and ventilation provided in the halls. All halls are air-conditioned.  
Fire safety Hose reels, extinguishers  
Security system CCTV system which covers the common areas and main access to the venue  

Note: Subject to change without prior notice.